Parameter
Symbol
Standard Conditions
of Test
Unit
F47
F44
F5
F5A
F6
F9
F9C
F10
F57
F39
F8
P10
P11
P12
F58
FB2
FB3
F9Q
F9N
F65*
F82
FT6
FT7
FTA
Initial Permeability
(nominal)
µi
B<0.1mT 10kHz
25°C
-
1800
± 20%
1900
± 20%
2000
± 20%
2500
± 20%
1800
± 20%
4400
± 20%
5000
± 20%
6000
± 20%
7500
± 25%
10000
± 30%
1200
min
2000
± 20%
2250
± 20%
2000
± 20%
750
± 20%
2000
± 20%
2700
± 20%
2300
± 20%
4000
± 20%
4400
± 40%
5000
± 20%
6000
± 20%
7500
± 25%
10000
± 30%
Saturation Flux
Density (typical)
Bsat
H=796 A/m 10 Oe
25°C Static 100°C
mT
470
350
500
400
470
350
470
350
350
-
380
-
460
-
380
-
380
-
380
-
380
-
-
-
-
-
-
-
>420
480
480
350*
-
410
-
350
460
430
420
420
Remanent Flux
Density (typical)
Br
H0 (from near saturation)
10 kHz 25°C
mT
130
270
200
150
-
180
170
100
250
200
-
120
70
35
-
140
140
190
270
100
170
150
130
180
Coercivity (typical)
Hc
B0 (from near saturation)
10 kHz 25°C
A/m
24
27
21
15
-
13
13
14
17
16
-
22
18
7
-
10
10
24
15
14
13
15
10
8
Loss
Factor
(maximum)
![]()
B<0.1mT 25°C
10 kHz
100 kHz
200 kHz
1 MHz
10-6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
20
-
-
-
20
-
-
-
20
-
-
-
-
-
-
-
-
-
-
-
-
-
-
6
15
-
-
1.5
5
-
-
0.8
2.5
-
-
-
-
-
-
30
-
-
-
15
-
-
-
-
20
-
-
-
30
-
-
-
20
-
-
-
20
-
-
-
25
6
50
-
-
6
50
-
-
Temperature Factor
![]()
B<0.1mT 10kHz
+25°C to +55°C
B<0.1mT 10kHz
0°C to +25°C
10-6/°C
-
-
-
-
-
-
-
-
-
-
0 to 2
-
-1 to +2
-
-1 to +2
-
-
-
-
-
-
-
0 to 2
-
.5 to 1.5
-
.4 to 1.0
-
-
-
-
-
-
-
-
-
-
-
-
-
-1 to +2
-
-
-
-
-
-1 to 0
-0.5 to +0.5
Curie Temperature (minimum)
TC
B<0.1mT 10kHz
°C
200
230
200
200
180
130
160
130
125
125
130
150
150
150
310
230
230
140
150
>150
160
140
150
150
Disaccomodation
Factor (max)
![]()
B<0.25mT 10kHz
50°C 10 to 100 mins
10-6
-
-
-
-
-
-
-
-
-
-
-
8
4
3
-
-
-
-
-
-
-
-
-
-
Hysteresis Material
Constant (max)
![]()
B from 1.5 to 3mT 10kHz
25°C
10-6/mT
-
-
-
-
-
-
-
-
-
-
-
2.4
0.8
0.45
-
-
-
-
-
-
-
-
-
-
Resistivity (typical)
![]()
1V/cm 25°C
-cm
100
100
100
100
100
50
50
50
100
100
100
100
100
100
100
100
100
20
20
20
50
20
10
10
Amplitude
Permeability
(minimum)
µa
400mT 25°C
320mT 100°C
340mT 100°C
µa
-
-
-
2500
-
1900
2500
-
1900
Total Power
Loss Density
(maximum)
Pv
200mT; 16kHz : 25°C
200mT; 16kHz : 60°C
200mT; 16kHz : 100°C
200mT; 25kHz : 25°C
200mT; 25kHz : 60°C
200mT; 25kHz : 100°C
100mT; 100kHz : 25°C
100mT; 100kHz : 100°C
200mT; 100kHz : 100°C
50mT; 400kHz : 25°C
50mT; 400kHz : 100°C
mW/cc
-
-
-
-
-
-
-
-
-
-
-
-
-
-
200
-
130
250
160
750
-
-
-
-
-
200
-
130
250
160
750
-
-
* Bsat measured at H=1200 A/m